Supination and Pronation Dynasplint® System for the Forearm


 
 

Pronation Dynasplint® System

Supination Dynasplint® System

 
 

     
 

COMMON DIAGNOSES:


Radial head fractures

Elbow dislocations

Elbow fractures

Radial or ulnar fractures

Open reduction internal fixation (ORIF)

Colles’ fractures

Wrist fractures

Tendon and ligament repairs

MEASUREMENTS:

Forearm Pronation/Supination (Adult)  
 
Weight 3 lb 14.4 oz / 1.77 kg
Range of Length 8.75 – 15.75 in / 22.23 – 40.01 cm
Range of Motion 0° neutral to 180° supination/0° neutral to 180° pronation

THE REBOUND EFFECT:
“High-force, short-duration stretching favors recoverable, elastic tissue deformation, whereas low-force, long-duration stretching enhances permanent plastic deformation…In the clinical setting, high force application has a greater risk of causing pain and possibly rupture of tissue.*” Dynasplint® Systems improve range of motion by creating permanent, non-traumatic tissue elongation and remodeling, thus virtually eliminating the range of motion rebound effect often observed in the clinical setting.*  

 

 

“The Dynasplint® System is a product I have used for years for patients with limited range of motion. In most cases, range of motion rehabilitation time is significantly reduced, therefore lowering costs and increasing patients satisfaction with their results. The Dynasplint® System is much more effective compared to other products on the market.”

-Charles M. Creasman, MD; Arizona Orthopedic and Fracture Surgeons, Phoenix, AZ


*Hepburn GR, et al: Multi-Center Clinical Investigation on the Effect of Incorporating Dynasplint® Treatment into Standard Physical Therapy Practice for Restoring Range of Motion of Elbows and Knees, presented at the New York APTA State Chapter Meeting, New York, NY, April 26, 1985.

Hepburn GR: Case Studies: Contracture and Stiff Joint Management with Dynasplint®. The Journal of Orthopaedic and Sports Pysical Therapy, Vol 8, No 10: 498-504, April 1987.

Coverdale J, et al: Does a Uni-directional Dynamic Splint Affect Bi-directional Wrist ROM Scientific and Clinical Paper Presentation. American Society of Hand Therapists Annual Meeting, September 21, 2002.

Johnson BM, Flynn MJG, Beckenbaugh RD: A Dynamic Splint for Use After Total Wrist Arthroplasty. The American Journal of Occupational Therapy, 35: 179-184, March 1981.

McPherson JJ, Becker AH: Dynamic Splint to Reduce the Passive Component of Hypertonicity. Archives of Physical Medicine and Rehabilitation, Vol 66: 249-252, April 1985.

 

 

 

Copyright © 2006 Dynasplint Systems, Inc. All rights reserved.